Abstract
This paper proposes a multi-objective optimal dispatch strategy for dispatchable distributed generation units in an AC-DC hybrid microgrid. The proposed method determines optimal droop values of dispatchable distribution generation units to minimize total operation cost and emission in an AC-DC hybrid microgrid. Two objectives (minimization of operation cost and emission) are represented in the fuzzy domain by fuzzy membership functions. The membership function having the minimum value is considered as the membership value of the aggregated objective. The membership function value of the aggregated objective is maximized to obtain the optimal solution. Optimization is carried out using particle swarm optimization technique. A 6-bus AC-DC hybrid microgrid test system is used for the simulation study. Simulation results demonstrate the potency of the suggested method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.