Abstract

Venous congestion results in tissue damage and remains the most common failure of free microvascular transfer if it is not recognized early. The purpose of this experimental study was to evaluate venous congestion and describe the findings with two different monitoring tools. A standardized epigastric flap was raised, and total occlusion of the draining vein was temporarily applied for 4, 5, 6, or 7 h. Blood flow measurements, including laser-Doppler flowmetry, and tissue spectrophotometry (O2C) and indocyanine green (ICG) videoangiography using the FLOW® 800 tool, were performed systematically after each surgical step, an interval of venous occlusion, and 1 week of clinical observation. Both monitoring tools were capable of detecting acute venous occlusion. ICG videoangiography data showed a significant decrease in the first and second maximum, and the area under the curve, during venous occlusion, whereas hemoglobin levels in the O2C analysis remained stable. Changes in fluorescence values in border areas of the flap correlated significantly with the incidence of necrosis. O2C data later showed significant correlation with the area of necrosis, and more individual changes during flap monitoring. ICG videoangiography might therefore be useful in the prediction of flap necrosis in critical areas of perfusion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.