Abstract

A multimicrophone method for measurement of the acoustic absorption of small material samples using impedance tubes is presented. The multimicrophone method may be implemented with actual or synthetic microphone arrays, the latter involving successive measurements and a roving microphone, and is an alternative to the two-microphone method of ASTM E 1050. The effects of absorption measurement inaccuracy due to microphone response (magnitude and phase) bias and measurement noise are determined by simulation. Simulation results indicate that the multimicrophone method is more robust against microphone bias and noise and is therefore more accurate than the standard method, especially as microphone counts increase, while requiring minimal additional effort and cost.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.