Abstract

A rapid time-series of T2*-weighted magnetic resonance (MR) images acquired during the first pass of a bolus injection of a paramagnetic MR contrast agent provides a basis for estimating cerebral perfusion. The concentration versus time of the contrast agent is calculated in a single image plane on a pixel-wise basis. A number of hemodynamic parameters can be extracted from the integral of the concentration-time curve, hence a method for obtaining an efficient and accurate estimate of the area under the curve is essential for the assessment of perfusion images. A new, automatic, multilevel processing method for calculating area under the concentration-time curve is proposed. In the first level of processing, the signal-to-noise ratio (SNR) is estimated for every pixel, and, if satisfactory, the limit points of integration are determined. An averaging filter is applied on the concentration-time curve, and the slope of the output of the filter Is calculated. The thresholds for initial and final integration points are determined next and are used to obtain limit points of integration. At this level, some pixels may be left without computed limits. These are determined at the next level of processing, using the median filter applied on the pixel neighborhood limit points. After determining limit points, the conventional method for integration is used to obtain the area under the curve. Tests of the proposed method are described for both simulated and real data. The simulated data are based on the gamma-variate function, with white noise added. The parameters used are obtained from fitting the gamma-variate function for regions within white matter, gray matter and cerebrospinal fluid in real perfusion images. The results obtained by the proposed estimator compare very favorably with the theoretical values for the particular cases studied. The performance of the proposed method for measuring cerebral hemodynamic parameters is also discussed when applied to perfusion studies in patients performed on a GE Signa 1.5 T, Advantage, whole body scanner. The results compare well with a previously used procedure based on slice-averaged time of arrival of the contrast bolus and manually determined limiting points. The new method automatizes the integration limit selection procedure efficiently, and is based on local, rather than global calculations. The procedure is simple and fast, and can perform numerical integration of 128*256 pMRI images in less than a second on a Sun SPARC 2 workstation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.