Abstract

Local high-accuracy velocity estimation is important for the ultrasound-based evaluation of regional myocardial function. The ultrasound phase difference at the center frequency of the transmitted signal has been conventionally used for velocity estimation. In the conventional method, spatial averaging is necessary owing to the frequency-dependent attenuation and interference of backscattered waves. Here, we propose a method for suppressing these effects using multifrequency phase differences. The resulting improvement in velocity estimation in the heart wall was validated by in vivo experiments. In the conventional method, the velocity waveform exhibits spike-like changes. The velocity waveform estimated using the proposed method did not exhibit such changes. Because the proposed method estimates myocardium velocity without spatial averaging, it can be used for measuring heart wall dynamics involving thickness changes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.