Abstract

The multifrequency binary sequence experimental technique for measuring closed-loop frequency response functions has been implemented at the fast flux test facility for routine surveillance activities. The frequency content of the standard rod movement sequence has been shown to be sufficient to normalize the data at moderate frequencies. This obviates the need for auxiliary calibration measurements and provides the reactivity worth of the test control rod. Analyses of a series of tests conducted in 1986 illustrate that the rod worths inferred from the tests are consistent with zero-power measurements. Also, the dependence of the prompt feedback time constant on reactor conditions was determined.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.