Abstract

To investigate multifocal visual evoked potentials (mfVEP) of the amblyopic and fellow eye in amblyopia due to anisometropia. We recorded mfVEP in both eyes of 15 anisometropic amblyopic patients and 15 normal control subjects. The responses from the central 7.0 degrees arc of the visual field were measured, and changes in latency and amplitude were compared between the amblyopic, fellow, and normal control eyes. There was a significant difference in the latency and amplitude of mfVEP between the amblyopic and fellow eyes. The responses in the central region of the visual field (rings 1 and 2) had a longer latency and smaller amplitude in the amblyopic eye. In contrast, there was no difference in mfVEP latency or amplitude between the fellow eye and normal control eyes. These results suggest that mfVEP may be used as an alternative objective method for diagnosis and monitoring of anisometropic amblyopia.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.