Abstract
In a two-stage solid-state transformer (SST) cell, the grid power pulsates at the double-line frequency, yielding second-order harmonic current (SHC) across the unit. SHC into the DC/DC stage causes extra losses in the semiconductors and magnetics, resulting in reduced efficiency and lifetime at the gain of lower DC-link requirement. This paper investigates how the DC-link design affects the SHC distribution using a proposed impedance model, which in turn impacts losses, volume and overall reliability. Particularly, the overall lifetime is evaluated considering the reliability interactions between components resulting from varied DC-link design. The newly introduced reliability dimension provides further insight into the DC-link design, in addition to the voltage ripple requirement and efficiency-power density tradeoff. The model and design concept are verified by the simulation and experiment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.