Abstract

The aim of our study was to assess the accuracy of multidetector row CT angiography (MDCTA) in the detection of the underlying vascular abnormalities causing spontaneous lobar intracerebral hemorrhage (ICH) compared with conventional digital subtraction angiography (DSA). Seventy-eight patients who underwent MDCTA with use of a 16-detector row scanner and DSA were prospectively included in this study. Each study was assessed by 2 independent blinded neuroradiologists; decisions were made in consensus. Findings on CT angiograms, including the original axial data, multiplanar reformations, and volume-rendered images with and without automated bone segmentation, were used to identify the underlying causes of ICH. Twenty-two of the 78 patients (28.2%) exhibited angiographic abnormalities, including aneurysms of the proximal arteries (n = 9), arteriovenous malformations (n = 7), Moyamoya disease (n = 4), and aneurysms of the distal arteries (n = 2). MDCTA detected the underlying vascular abnormalities in 21 patients except 1 case of small arteriovenous malformation. Overall sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of MDCTA for detection of underlying vascular abnormalities were 95.5%, 100%, 100%, 98.2%, and 98.7%, respectively. MDCTA is a highly accurate imaging technique in the diagnosis of underlying vascular abnormalities in patients with spontaneous lobar ICH.

Highlights

  • AND PURPOSE: The aim of our study was to assess the accuracy of multidetector row CT angiography (MDCTA) in the detection of the underlying vascular abnormalities causing spontaneous lobar intracerebral hemorrhage (ICH) compared with conventional digital subtraction angiography (DSA)

  • Lobar ICH is a separate group of supratentorial hemorrhage and the result of heterogeneous etiologies, including aneurysms, arteriovenous malformations (AVMs), amyloid angiopathy, cavernous angiomas, vasculitis, primary or metastatic tumors, Moyamoya diseases, cerebral venous thromboses, systemic hypertension, bleeding diatheses, and sympathomimetic drugs.[1]

  • When compared with DSA, CT angiography (CTA) is a noninvasive imaging technique, which has proved valuable for identifying cerebrovascular lesions

Read more

Summary

Objectives

The aim of our study was to assess the accuracy of multidetector row CT angiography (MDCTA) in the detection of the underlying vascular abnormalities causing spontaneous lobar intracerebral hemorrhage (ICH) compared with conventional digital subtraction angiography (DSA). The purpose of our study was to compare prospectively the effectiveness of 16-channel MDCTA with that of conventional DSA in the detection of the underlying vascular abnormalities causing spontaneous lobar ICH

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.