Abstract

With the aim to develop a new gas chromatography–mass spectrometry method to analyze 24 pesticide residues in baby foods at the level imposed by established regulation two simple, rapid and environmental-friendly sample preparation techniques based on QuEChERS (quick, easy, cheap, effective, robust and safe) were compared – QuEChERS with dispersive liquid-liquid microextraction (DLLME) and QuEChERS with dispersive solid-phase extraction (d-SPE). Both sample preparation techniques achieved suitable performance criteria, including selectivity, linearity, acceptable recovery (70–120%) and precision (⩽20%). A higher enrichment factor was observed for DLLME and consequently better limits of detection and quantification were obtained. Nevertheless, d-SPE provided a more effective removal of matrix co-extractives from extracts than DLLME, which contributed to lower matrix effects. Twenty-two commercial fruit-based baby food samples were analyzed by the developed method, being procymidone detected in one sample at a level above the legal limit established by EU.