Abstract

Myocardial infarction (MI) is a medical emergency for which the early detection of symptoms is desirable. The prevalence of portable electrocardiogram (ECG) devices makes frequent screening for MI possible. In this study, we develop an MI classifier that combines both convolutional and recurrent neural networks, and is suitable for wearable ECG devices with only a single lead recording. It performs multiclass classification to discriminate the ECG records of MI from those of healthy individuals and patients with existing chronic heart conditions, as well as ECG records contaminated with noise. The method was tested on a dataset with MI ECG records and compared with a pure convolutional neural network and classifier with hand-crafted features. It was found that the addition of a recurrent layer improved the classification sensitivity by 28.0% compared to the convolutional neural network alone. Overall, it achieved 92.4% sensitivity, 97.7% specificity, a 97.2% positive predictive value, and a 94.6% F1 score.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.