Abstract

to assess the safety and efficacy of APERTO-Paclitaxel-coated balloon angioplasty versus standard angioplasty for the treatment of dysfunctional hemodialysis shunts and native arteriovenous fistulae. consecutive patients with dysfunctional dialysis related to underlying efferent vein stenosis were included and randomized 1:1 to either APERTO-paclitaxel drug-coated balloon (study arm) or standard percutaneous transluminal angioplasty (control arm). Primary endpoint is time from treatment until dialysis access dysfunction according to standardized Kidney Disease Outcomes Quality Initiative (KDOQI)-guidelines and assessed by Kaplan-Meier survival curves and tested for significance with log-rank analysis. Secondary endpoints include device, technical, and clinical success of the index angioplasty procedure. The study included 103 patients (n=51 study-group) with a de novo (n=33) dysfunctional native arteriovenous fistula (n=79) in the forearm (n=60). The majority of included patients were male with a mean age of 69.8 years, presenting with a dysfunctioning autologous arteriovenous fistula in the forearm. Device-related complications did not occur in any of the included patients. Functional hemodialysis access without need for re-intervention at 1 year after index procedure was found in n=10 (19.6%) and n=5 (9.6%) of patients treated with, respectively, paclitaxel drug-coated balloon and percutaneous transluminal angioplasty (p=0.612). A nonsignificant benefit of paclitaxel drug-coated balloon (n=5; 25%) over percutaneous transluminal angioplasty (n=1; 11%) was found (p=0.953) in de novo lesions in autologous fistulas. APERTO-paclitaxel drug-coated balloon is a safe balloon catheter to manage dysfunctional hemodialysis access; however, longer period of adequate hemodialysis circuit functioning after endovascular index stenosis treatment, using APERTO-paclitaxel drug-coated balloon versus percutaneous transluminal angioplasty could not be demonstrated. APERTO-paclitaxel drug-coated balloon catheter is a safe device to manage dysfunctional hemodialysis access. Compared to conventional angioplasty balloon, the APERTO drug-coated balloon will not result in longer period of adequate hemodialysis circuit functioning. A non-significant benefit of APERTO drug-coated balloon was found in de novo lesions in autologous fistulas.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.