Abstract

Abstract This article deals with determining of fatigue lifetime of aluminum alloy 6063-T66 during by multiaxial cyclic loading. The experiments deal with the testing of specimens for identification of the strain-life behavior of material, the modeling of combined loading and determining the number of cycles to fracture in the region of low-cycle fatigue. Fatigue tests under constant amplitude loading were performed in a standard electromechanical machine with a suitable gripping system. Based on the experimental results the fatigue design curves are compared to the fatigue data from the base material and the welded material and also multiaxial fatigue models, which are able to predict fatigue life at different loads.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.