Abstract

The Multi-angle Imaging SpectroRadiometer (MISR) consists of nine cameras pointing from nadir to an extreme of 70.5/spl deg/ in the view angle. It is a pushbroom imager with four spectral bands per camera. Instrument specifications call for each camera to be calibrated to an absolute uncertainty of 3% and to within 1% relative to the other cameras. To accomplish this, the MISR instrument utilizes an on-board calibrator (OBC) to provide updates to the instrument gain coefficients on a bimonthly basis (i.e. once every two months). Spectralon diffuse panels are used in the OBC to provide a uniform target for the nine MISR cameras to view. The radiometric scale of the OBC is established through the use of photodiodes. The stability of the MISR OBC system and its in-flight calibration are discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.