Abstract

To develop a novel multi-contrast four-dimensional magnetic resonance imaging (MC-4D-MRI) technique that expands single image contrast 4D-MRI to a spectrum of native and synthetic image contrasts and to evaluate its feasibility in liver tumor patients. The MC-4D-MRI technique integrates multi-parametric MRI fusion, 4D-MRI, and deformable image registration (DIR) techniques. The fusion technique consists of native MRI as input, image pre-processing, fusion algorithm, adaptation, and fused multi-contrast MRI as output. Four-dimensional deformation vector fields (4D-DVF) were generated from an original T2/T1-w 4D-MRI by deforming end-of-inhalation (EOI) to nine other phase volumes via DIR. The 4D-DVF were applied to multi-contrast MRI to generate a spectrum of 4D-MRI in different image contrasts. The MC-4D-MRI technique was evaluated in five liver tumor patients on tumor contrast-to-noise ratio (CNR), internal target volume (ITV) contouring consistency, diaphragm motion range, and tumor motion trajectory; and in digital anthropomorphic phantoms on 4D-DIR introduced errors in tumor motion range, centroid location, extent, and volume. MC-4D-MRI consisting of 4D-MRIs in native image contrasts (T1-w, T2-w, and T2/T1-w) and synthetic image contrasts, such as tumor-enhanced contrast (TEC) were generated in five liver tumor patients. Patient tumor CNR increased from 2.6±1.8 in the T2/T1-w MRI, to -4.4±2.4, 6.6±3.0, and 9.6±3.9 in the T1-w, T2-w, and TEC MRI, respectively. Patient ITV inter-observer mean Dice similarity coefficient (mDSC) increased from 0.65±0.10 in the original T2/T1-w 4D-MRI, to 0.76±0.14, 0.77±0.12, and 0.86±0.05 in the T1-w, T2-w, and TEC 4D-MRI, respectively. Patient diaphragm motion range absolute differences between the three new 4D-MRIs and original T2/T1-w 4D-MRI were 1.2±1.3, 0.3±0.7, and 0.5±0.5mm, respectively. Patient tumor displacement phase-averaged absolute differences between the three 4D-MRIs and the original 4D-MRI were 0.72±0.33, 0.62±0.54, and 0.74±0.43mm in the superior-inferior (SI) direction, and 0.59±0.36, 0.51±0.30, and 0.50±0.24mm in the anterior-posterior (AP) direction, respectively. In the digital phantoms, phase-averaged absolute tumor centroid shift caused by the 4D-DIR were at or below 0.5mm in SI, AP, and left-right (LR) directions. We developed an MC-4D-MRI technique capable of expanding single image contrast 4D-MRI along a new dimension of image contrast. Initial evaluations in liver tumor patients showed enhancements in image contrast variety, tumor contrast, and ITV contouring consistencies using MC-4D-MRI. The technique might offer new perspectives on the image contrast of MRI and 4D-MRI in MR-guided radiotherapy.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call