Abstract

The oxidative degradation of polyethylene in various conditions has been studied. In order to gain insight into the oxidation process, a method for the curve-fitting analysis of the IR carbonyl band between 1800 cm −1 and 1600 cm −1 in oxidized low-density polyethylene (LDPE) has been developed. Up to 10 components were needed to fit the band envelope, whose assignments and peak positions were based on the literature and on the synthesis of an appropriate model compound. The determination of the other band parameters, such as peak width and peak shape, necessary for reliable best fitting of the absorbance envelopes, was obtained by overall fitting optimization process. By using the available extinction coefficients, the quantitative determinations of the main oxidized species, i.e. ketones, carboxylic acids, esters, γ-lactones and ketoacids, were obtained with a reasonable confidence by rigorous parameter setting. The method was applied to the IR analysis of LDPE samples oxidized in different conditions (under thermal and irradiation stimulation), either as beads or films, as a function of time. Total hydroperoxide concentrations were also quantitatively estimated by a modified iodometric titration procedure. A good linear correlation between concentrations estimated by chemical titration and by intensity analysis of the free hydroperoxide IR band was observed.