Abstract

Abstract An analytical, two-dimensional, multi-region, multi-cell technique was developed for the thermal analysis of LMFBR rod bundles. Local temperature fields of various unit cells were obtained for seven- and nineteen-rod bundles of different geometries and power distributions. The validity of the technique was verified by its excellent agreement with the THTB calculational result. By comparing the calculated fully-developed circumferential cladding temperature distribution with those of the experimental measurements, an axial correction factor has been derived to account for the entrance effect under practical conditions. A scheme was also developed to couple the two-dimensional distributed analysis and lumped parameter calculation such that the entrance effect can be implanted into the distributed parameter analysis. The technique has demonstrated its applicability for a seven-rod bundle. The results of calculation were compared to those of three-dimensional analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.