Abstract
Abstract An exact transient analytical solution of the temperature fields and heat fluxes for the modified transient plane source (MTPS) method is presented. The MTPS sensor is made of a thin disk with a heater/sensor and a heated guard ring on its surface, providing a one-dimensional heat flow to a semi-infinite sample in contact with its surface. The MTPS sensor measures the thermal effusivity of the sample. Two different solutions are derived, one is in the form of an infinite series with no thermal resistance, and the other is in integral form and includes thermal resistance between the MTPS sensor surface and the measured sample. The theoretical model is supplemented by experimental results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.