Abstract
The Multigap Resistive Plate Chambers (MRPC) are used as a timing detector in several particle physics and cosmic ray experiments. The gas mixture of MRPC at current experiments is a mixture containing C2F4H2 and in some cases SF6. C2F4H2 and SF6 have a Global Warming Potential (GWP) of 1430 and 23900 respectively, therefore they are classified as greenhouse gases. The studies to reduce the amount of emission of the greenhouse gas in high energy experiments are underway; the present contribution has been performed as part of this effort. The results have been obtained from the beam test of a small MRPC which has 6 gaps of 220 μm and a sensitive area of 20 × 20 cm2. It has been operated with the ecological HFO-1234ze gas (C3F4H2), and with the C2F4H2/SF6 mixture. We have found that the ecological gas can substitute for the C2F4H2-based gas mixture without significantly compromising the current level of performance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.