Abstract

The potential use of alanine as an MRI contrast agent was investigated. The relaxation properties of alanine solutions were measured at 9.4 T. The T2 relaxivity caused by the chemical exchange (R2ex) between amine protons and water protons was 0.10 mM−1 s−1 at 37 °C. As a demonstration, alanine uptake in a mouse xenograft model of U-87 MG glioblastoma was measured using MRI, and was compared with immunohistochemistry staining of ASCT2, a transporter that imports amino acids into cancer cells. Statistically significant (p = 0.0079) differences in ASCT2 distribution were found between regions that show strong and weak alanine uptake in MRI. To better understand the influence of perfusion, the effect of ASCT2 inhibition on the alanine uptake in MRI was investigated, and dynamic contrast enhanced MRI was compared with alanine MRI.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.