Abstract

A 50-year-old man presented to the out-patient clinic because of a sudden pain in his left eye just after lumbal magnetic resonance imaging (MRI) was started. Biomicroscopic examination of the left eye revealed the inferior anterior chamber angle including a foreign body and the superior anterior chamber angle including the iris portion, into which the foreign body had been stuck prior to the MRI examination. His history revealed an accidental penetrating eye trauma of the shotgun pellet of 28 years ago. The foreign body was easily removed using a forceps intraoperatively. The foreign body was defined as a metallic foreign body postoperatively.