Abstract

Background Our aim was to evaluate the prognostic value of magnetic resonance imaging (MRI)-based ratio of fetal lung volume (FLV) to fetal body volume (FBV) as a marker for development of chronic lung disease (CLD) in fetuses with congenital diaphragmatic hernia (CDH). Patients and Methods FLV and FBV were measured and the individual FLV/FBV ratio was calculated in 132 fetuses. Diagnosis of CLD was established following prespecified criteria and graded into mild/moderate/severe if present. Logistic regression analysis was used to calculate the probability of postnatal development of CLD in dependence of the FLV/FBV ratio. Receiver operating characteristic curves were analysed by calculating the area under the curve to evaluate the prognostic accuracy of this marker. Results 61 of 132 fetuses developed CLD (46.21%). The FLV/FBV ratio was significantly lower in fetuses with CLD (p=0.0008; AUC 0.743). Development of CLD was significantly associated with thoracic herniation of liver parenchyma (p<0.0001), requirement of extracorporal membrane oxygenation (ECMO) (p<0.0001) and gestational age at delivery (p=0.0052). Conclusion The MRI-based ratio of FLV to FBV is a highly valuable prenatal parameter for development of CLD. The ratio is helpful for early therapeutic decisions by estimating the probability to develop CLD. Perinatally, gestational age at delivery and ECMO requirement are useful additional parameters to further improve prediction of CLD.