Abstract

BackgroundVarious diagnostic modalities are available to assess the problematic knee arthroplasty. Visualization of soft‐tissue structures in relation to the arthroplasty and bone remains difficult. Recent developments in MRI sequences could make MRI a viable addition to the diagnostic arsenal.PurposeTo review the diagnostic properties of MRI, to identify certain causes of complaints that may be directly related to implant failure of total (TKA) or unicompartmental knee arthroplasty (UKA); infection, loosening and wear, instability, malalignment, arthrofibrosis, or patellofemoral problems.Study TypeSystematic review.PopulationTwenty‐three studies were included: 16 TKA, four UKA, and three cadaveric studies. Causes of knee arthroplasty complaints analyzed were; infection (three), loosening and wear (11), malalignment (five) and instability (four).Field Strength and SequencesNo field strength or sequence restrictions.AssessmentPubMed, SCOPUS, and EMBASE were searched. Risk of bias was assessed using the COnsensus‐based Standards for the selection of health Measurement Instruments (COSMIN) and the QUality Assessment of Diagnostic Accuracy Studies‐2 (QUADAS‐2).Statistical TestsThe results of the original research articles are stated.ResultsFifteen studies assessed the reproducibility of analyzing infection, loosening and wear, and malalignment. Fourteen of 15 studies were deemed as adequate to good quality. Results showed a moderate to excellent agreement (ICC/K 0.55–0.97). Fourteen studies addressed the accuracy. For infection and loosening and wear the sensitivity and specificity estimates varied between 0.85–0.97 and 0.70–1.00, respectively. The accuracy for malalignment was excellent (r ≥ 0.81). For these studies QUADAS‐2 analysis suggested few risks of bias. A meta‐analysis was not possible due to the heterogeneity of the data.Data ConclusionThis study supports that MRI can be used with overall reproducible and accurate results for diagnosing infection, loosening and wear, and malalignment after knee arthroplasty. Nonetheless, studies regarding the diagnosis of instability, arthrofibrosis or patellofemoral complaints using MRI are limited and inconclusive. Level of Evidence: 3 Technical Efficacy: Stage 2J. Magn. Reson. Imaging 2020;51:446–458.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.