Abstract
In this paper, a modified version of Variable Structure Model Reference Adaptive Controller (VS-MRAC) scheme is developed for an application in Fault Tolerant Control (FTC) of a Single Input-Single Output (SISO) process. As a result of steady state error and oscillations when faults are induced in sensor and actuator of the process, the original VS-MRAC is modified by adding a Saturation Function and a PI controller (VS-MRAC-SAT-PI). The new scheme performance is compared against a classical PID and two other MRAC-based FTC schemes in a Coupled-Tank System. Different types of additive faults (abrupt and gradual faults) were induced in the process and results showed better fault accommodation capabilities of the VS-MRAC-SAT-PI.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.