Abstract

You have accessJournal of UrologyUrodynamics/Lower Urinary Tract Dysfunction/Female Pelvic Medicine: Female Incontinence: Therapy III1 Apr 2018MP75-11 FUNCTIONAL OUTCOMES OF ADJUSTABLE CONTINENCE THERAPY BALLOONS IN WOMEN : A MULTICENTRIC RETROSPECTIVE STUDY Claire Sanson, Pauline Guiffart, Benoît Peyronnet, Xavier Gamé, and Xavier Biardeau Claire SansonClaire Sanson More articles by this author , Pauline GuiffartPauline Guiffart More articles by this author , Benoît PeyronnetBenoît Peyronnet More articles by this author , Xavier GaméXavier Gamé More articles by this author , and Xavier BiardeauXavier Biardeau More articles by this author View All Author Informationhttps://doi.org/10.1016/j.juro.2018.02.2103AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookTwitterLinked InEmail INTRODUCTION AND OBJECTIVES To assess efficacy and safety of the adjustable continence therapy device (ACT) in the treatment of female pure stress (SUI) or mixed urinary incontinence (MUI). METHODS This is a multicentric retrospective study. All women undergoing ACT device placement between 2008 and 2016 to treat SUI or MUI within one the 3 participating centers were considered eligible. The last consultation marked the end of the follow-up period. Regarding efficacy, the improvement in urinary incontinence was subjectively assessed by the woman herself using a numbered rating scale (NRS) from 0 to 10. Success was defined by a NRS > 8, while improvement was defined by a NRS between 0 and 8, and failure by a NRS = 0, at the end of the follow-up period. The continence was also assessed using the PGI-I (Patient's Global Impression of Improvement). Regarding safety, per- and post-operative complications were retrieved. Early complications (<30 days) were reported according to the Clavien-Dindo classification. RESULTS Eighty-eight women with a mean age of 68 yo (20-90) were included. Among them, 25.0% had an underlying neurologic disease, 10.2% had a history of pelvic radiation therapy, and 79.5% had already undergone previous surgery for urinary incontinence (mean number of surgery was 1.5). 51.1% presented with SUI. After a mean follow-up period of 21.0 months (1-76), 25 patients (28.4%) achieved success, 28 patients (31.8%) showed improvement, and 35 patients (39.8%) were considered in failure. Considering all included women, PGI-I was quoted as 1, 2, 3 and 4 by 12 (13.6%), 17 (19.3%), 24 (27.3%) and 33 (37.5%) of them, respectively. Only two patients reported a PGI-I > 4. Mean volume per balloon was 3.5ml, with a mean of 3.3 balloon inflations. Among the 88 procedures, 6 per-operative complications (6.8%) were noted (vesical or vaginal injury), while 16 early post-operative complications (18.2%) were reported (all grade I or II, to the Clavien-Dindo classification). Late complications (infection, erosion or balloon migration) occurred in 18 patients (20.5%) and explantation was finally required in 29 patients (33.0%) (complication or failure). All complications resolved without any sequelae. CONCLUSIONS The ACT device implantation showed a limited efficacy, with a success or improvement rate of 60.2%. However, it was counterbalanced by an interesting safety profile, with no severe complication. These results should be interpreted with caution considering the high previous urinary incontinence surgery rate as well as the high neurogenic urinary incontinence among the studied population. © 2018FiguresReferencesRelatedDetails Volume 199Issue 4SApril 2018Page: e1012-e1013 Advertisement Copyright & Permissions© 2018MetricsAuthor Information Claire Sanson More articles by this author Pauline Guiffart More articles by this author Benoît Peyronnet More articles by this author Xavier Gamé More articles by this author Xavier Biardeau More articles by this author Expand All Advertisement Advertisement PDF downloadLoading ...

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call