Abstract
You have accessJournal of UrologyCME1 Apr 2023MP72-07 TIME EFFICIENCY AND PERFORMANCE OF DISPOSABLE VERSUS REUSABLE CYSTOSCOPES: A PROSPECTIVE, RANDOMIZED BENCHTOP COMPARISON Catalina Baas, Ricky Chen, Daniel R. Peverini, John Hartman, Akin S. Amasyali, Rose Leu, Aviram Assidon, Joshua D Belle, Elizabeth Baldwin, and D. Duane Baldwin Catalina BaasCatalina Baas More articles by this author , Ricky ChenRicky Chen More articles by this author , Daniel R. PeveriniDaniel R. Peverini More articles by this author , John HartmanJohn Hartman More articles by this author , Akin S. AmasyaliAkin S. Amasyali More articles by this author , Rose LeuRose Leu More articles by this author , Aviram AssidonAviram Assidon More articles by this author , Joshua D BelleJoshua D Belle More articles by this author , Elizabeth BaldwinElizabeth Baldwin More articles by this author , and D. Duane BaldwinD. Duane Baldwin More articles by this author View All Author Informationhttps://doi.org/10.1097/JU.0000000000003340.07AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVE: While reusable cystoscopes (RCs) are commonly used for urologic procedures, bulky equipment and lengthy sterilization times can impact efficiency. Disposable cystoscopes (DCs) may offer advantages including increased availability, greater portability, and faster setup times. The aim of this study is to compare procedure times, cystoscope specifications, and physician satisfaction between RCs and DCs. METHODS: Ten urologists performed simulated bedside cystoscopies using a prospective, randomized, crossover study design. A 3D-printed bladder model with 22 target letters was positioned within a female mannequin pelvis. Each subject used both a new disposable Ambu aScope 4 Cysto and a reusable Olympus CYF-5 flexible cystoscope to identify the targets. Afterward, participants completed a satisfaction survey. Times required for supply-gathering, setup, cystoscopy, and cleanup were compared. Image definition, field of view, deflection angle, force required for deflection, irrigation rate, weight, and working length were also compared. RESULTS: The DCs required less time for supply-gathering (187.5 vs 289.4 s, p<0.05), setup (203.3 vs 327.5 s, p<0.01), and cleanup (183.7 vs 356.2 s, p<0.05) while cystoscopy times were similar (230.4 vs 274.1 s, p=0.58). Optical testing showed higher image definition for the DCs (6.30 vs 2.00 line pairs/mm, p<0.01), but a smaller field of view (67° vs 108°, p<0.01) and no adjustable optical settings. The DCs had increased deflection (214° up/182° down vs 198° up/109° down, p<0.01) but required more force to deflect 180° up (6.86 vs 4.46 N, p<0.01) and 90° down (4.66 vs 3.55 N, p<0.01). The RC was heavier (325 vs 159 g), had a shorter working length (37.5 vs 39.0 cm), and a faster irrigation rate at 200 cm H2O (494.1 vs 387.4 mL/min, p<0.01). Post-testing, deflection was reduced for two DCs, but optical qualities remained unchanged. Survey results showed higher ratings in time-efficiency (9.5/10 vs 6.2/10, p<0.01) and overall satisfaction (9.3/10 vs 7.9/10, p<0.01) for the DCs. No subjective difference was found in maneuverability or image quality. CONCLUSIONS: While DCs had better image quality, greater deflection, and were faster to assemble and disassemble, RCs had greater durability, more optical settings, wider field of view, faster irrigation rates, and required less force for deflection. Knowledge of the strengths and weaknesses of each device could assist surgeons in optimizing cystoscope utilization in specific clinical scenarios. Source of Funding: None © 2023 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 209Issue Supplement 4April 2023Page: e1026 Advertisement Copyright & Permissions© 2023 by American Urological Association Education and Research, Inc.MetricsAuthor Information Catalina Baas More articles by this author Ricky Chen More articles by this author Daniel R. Peverini More articles by this author John Hartman More articles by this author Akin S. Amasyali More articles by this author Rose Leu More articles by this author Aviram Assidon More articles by this author Joshua D Belle More articles by this author Elizabeth Baldwin More articles by this author D. Duane Baldwin More articles by this author Expand All Advertisement PDF downloadLoading ...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.