Abstract
You have accessJournal of UrologyUrodynamics/Incontinence/Female Urology: Basic Research I1 Apr 2014MP1-08 ASSESSMENT OF AUTONOMIC SENSORY FUNCTION WITH A NOVEL DEVICE IN THE MOUSE BLADDER Fuat Bicer, Jin Young Kim, Andrew Horowitz, Firouz Daneshgari, and Guiming Liu Fuat BicerFuat Bicer More articles by this author , Jin Young KimJin Young Kim More articles by this author , Andrew HorowitzAndrew Horowitz More articles by this author , Firouz DaneshgariFirouz Daneshgari More articles by this author , and Guiming LiuGuiming Liu More articles by this author View All Author Informationhttps://doi.org/10.1016/j.juro.2014.02.106AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookTwitterLinked InEmail INTRODUCTION AND OBJECTIVES Various diseases can cause altered afferent autonomic sensitivity of bladder, including diabetes, neurologic or vascular lesions, multiple sclerosis, recurrent infection, interstitial cystitis, pelvic pain syndrome. In current urologic clinical practice, to study autonomic and sensory bladder neuropathy, clinicians still rely on patients� self-reported bladder sensation during the filling phase of urodynamics. We developed and tested the efficacy of an implantable bladder device which, when combined with the Neurometer�, can be used to assess fiber specific afferent bladder sensation in the mouse. METHODS We developed an implantable bladder device that applies selective nerve fiber stimuli (250 Hz for small myelinated Aδ fibers and 5 Hz for unmyelinated C fibers) to the bladder mucosa in the mouse to determine bladder current perception threshold (CPT) values. We performed 4 experiments in 64 C57BL/6J mice to examine the effects of our device on voiding habits, assess the interobserver reliability of the sensory perception threshold and determine the effects of intravesical administration of resiniferatoxin and lidocaine on the sensory perception threshold. RESULTS Sensory perception threshold values obtained by 2 blinded, independent observers were not different from each other (p=0.74382). CPT values obtained at the 2 stimulation frequencies remained constant for at least 6 days after device implantation. A significant increase in CPT values after resiniferatoxin instillation was noted at a stimulus frequency of 5 Hz (p=0.01347), whereas intravesical lidocaine led to an immediate increase in CPT at 250 (p=0.0003) and 5 Hz (p=0.0001). The implantation led to an early decreased voided volume and increased frequency of voids at 4 days, although these parameters returned to close normal after 6 days. The implanted bladder histology reveals defect created by device and mild inflammatory changes in next areas. CONCLUSIONS Assessment of bladder afferent sensation with our newly developed device is feasible in mice. It provides CPTs that appear to be fiber-type selective for autonomic bladder afferent nerves. © 2014FiguresReferencesRelatedDetails Volume 191Issue 4SApril 2014Page: e4 Advertisement Copyright & Permissions© 2014MetricsAuthor Information Fuat Bicer More articles by this author Jin Young Kim More articles by this author Andrew Horowitz More articles by this author Firouz Daneshgari More articles by this author Guiming Liu More articles by this author Expand All Advertisement Advertisement PDF downloadLoading ...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.