Abstract

You have accessJournal of UrologyImaging/Radiology: Uroradiology I1 Apr 2017MP08-20 RAPID PHENOTYPING OF GENITOURINARY ANOMALIES IN MICE USING MICRO-CT Gene Huang, Marisol O'Neill, Meade Haller, Carolina Jorgez, and D.J. Lamb Gene HuangGene Huang More articles by this author , Marisol O'NeillMarisol O'Neill More articles by this author , Meade HallerMeade Haller More articles by this author , Carolina JorgezCarolina Jorgez More articles by this author , and D.J. LambD.J. Lamb More articles by this author View All Author Informationhttps://doi.org/10.1016/j.juro.2017.02.307AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookTwitterLinked InEmail INTRODUCTION AND OBJECTIVES Mouse models serve as an excellent tool for studying human disease. Yet, the small size of the mouse presents technical challenges in characterizing organ defects. The use of micro-computed tomography (micro-CT) in biomedical research has historically been limited to studying osseous structures. However, development of iodine staining techniques has allowed for improved ex vivo study of soft tissue structures. Images acquired through micro-CT allow for limitless virtual sectioning (as thin as 2 µm), a distinct advantage over traditional tissue sectioning. In this study, we demonstrate the successful use of iodine staining and micro-CT to rapidly phenotype genitourinary (GU) anomalies in mice. METHODS Mice GU specimens were excised, fixed in formalin, and dehydrated in 70% ethanol. Iodine staining was performed by soaking the tissue in 0.1 N iodine (Fluka). The specimen was suspended in agar in preparation for imaging. Images were acquired using the SkyScan 1272 High-Resolution X-Ray Microtomograph (Bruker microCT, Kontich, Belgium). A 0.5 µm aluminum filter was utilized. Imaging parameters were 5 µm and 11 µm pixel size for penis and kidney specimens, respectively, and 2016 x 1344 resolution. Images were reconstructed using NRecon (Bruker microCT) and visualized using 3D Slicer v4 (slicer.org). RESULTS Both embryonic and adult mice GU specimens were imaged. Micro-CT scan time varied with specimen size and desired resolution, but was at longest 120 minutes. Normal and pathologic GU phenotypes were characterized on three-dimensional, reconstructed images. Embryonic GU systems were examined, including a number of hydronephrotic kidneys (top left). Normal, hydronephrotic, duplex (top right), and polycystic kidneys (bottom left) were identified in adult specimens. Adult penile specimens (bottom right) were reconstructed to allow for morphometric measurements. CONCLUSIONS We demonstrate successful generation of three-dimensional, high-resolution, contrast-enhanced images of GU organs in the murine model using micro-CT. The use of micro-CT possesses a vast potential in rapid phenotyping and study of GU anomalies in the murine model. © 2017FiguresReferencesRelatedDetails Volume 197Issue 4SApril 2017Page: e99 Advertisement Copyright & Permissions© 2017MetricsAuthor Information Gene Huang More articles by this author Marisol O'Neill More articles by this author Meade Haller More articles by this author Carolina Jorgez More articles by this author D.J. Lamb More articles by this author Expand All Advertisement Advertisement PDF downloadLoading ...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.