Abstract
You have accessJournal of UrologyCME1 May 2022MP04-03 CAN HANDHELD POINT OF CARE ULTRASOUND PROBES RELIABLY MEASURE TRANSABDOMINAL PROSTATE VOLUME? A PROSPECTIVE RANDOMIZED STUDY Henry Wright, Hermen Brar, Fabrice Henry, Dillon Corrigan, and Smita De Henry WrightHenry Wright More articles by this author , Hermen BrarHermen Brar More articles by this author , Fabrice HenryFabrice Henry More articles by this author , Dillon CorriganDillon Corrigan More articles by this author , and Smita DeSmita De More articles by this author View All Author Informationhttps://doi.org/10.1097/JU.0000000000002521.03AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVE: Prostate gland volume (PGV) helps guide management for prostatic disease. The American Urological Association (AUA) benign prostatic hyperplasia (BPH) guidelines recommend PGV assessment prior to BPH surgery via one of the following: magnetic resonance imaging (MRI), trans rectal or trans abdominal ultrasound (TRUS/TAUS), or computed tomography (CT). Handheld ultrasound (HUS) probes show promise as point of care ultrasound (POCUS) for PGV, yet evidence is limited. Our objective was to independently evaluate the accuracy of two HUS probes (Butterfly IQ, Clarius C3) in measuring trans abdominal PGV compared to guideline imaging (MRI, TRUS, TAUS, or CT). METHODS: In this prospective clinical study, enrolled subjects were randomized in a 1:1 ratio to undergo HUS PGV measurement with either the Clarius or Butterfly probe. Demographics, urologic history, and PGV data were collected. Reliability was quantified by estimating the intraclass correlation coefficient (ICC) between the HUS and guideline imaging and its 95% confidence interval (R version 4.1.0). We used the following standard criteria: ICC <0.5: poor reliability; 0.5 ≤ ICC <0.75: moderate reliability; ICC ≥0.75: good reliability. RESULTS: 78 men were randomized (38 Butterfly, 40 Clarius). Baseline characteristics similar between groups (p >0.05). The mean PGV based on HUS and gold standard imaging was higher in the Clarius group compared to Butterfly (p=0.011 and 0.044, respectively). The ICCs were 0.78 (95% CI: 0.62, 0.88) and 0.71 (95% CI: 0.51, 0.83) for the Butterfly and Clarius probes, respectively (Table 1), indicating that the Butterfly IQ produced good reliability between HUS and reference measurements, and the Clarius C3 produced moderate reliability between HUS and reference measurements. CONCLUSIONS: When compared to guideline imaging, the Butterfly IQ demonstrated good reliability for PGV, in comparison to moderate reliability for the Clarius C3. Further studies evaluating these probes as POCUS for urologic diseases are warranted. Source of Funding: Cleveland Clinic Research Programs Committee Grant © 2022 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 207Issue Supplement 5May 2022Page: e57 Advertisement Copyright & Permissions© 2022 by American Urological Association Education and Research, Inc.MetricsAuthor Information Henry Wright More articles by this author Hermen Brar More articles by this author Fabrice Henry More articles by this author Dillon Corrigan More articles by this author Smita De More articles by this author Expand All Advertisement PDF DownloadLoading ...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.