Abstract

To monitor radioactivity passing through a vehicle such as a pedestrian, a car, a train or a truck, Radiation Portal Monitors (RMP) are commonly employed. These detection systems consist of a large volume detector set close to the potential source path. An alarm is then triggered when the signal rises over a threshold initially estimated in view of the natural background signal. The approach developed in this work makes use of several detectors in a network along the source path. The correlation detection approach is elaborated to take into account the temporal periodicity of the signals taken by all distributed sensors as a whole. This new detection method is then not based only on counting statistics but also on the temporal series analysis. Therefore, a specific algorithm has been developed in our laboratory for this security application and shows a significant improvement, especially in terms of detection probability increase and false alarm reduction. This paper presents the theoretical approach and promising results obtained by simulation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.