Abstract

An activated carbon moving bed system (10 to 100 acf m air flow) was tested for controlling VOC emissions from a commercial aircraft painting facility. The cross-flow moving adsorbent bed showed a VOC collection efficiency in the 77.1 to 99.6 percent range over a superficial gas velocity range of 27 to 185 ft/min (0.14-0.94 m/sec). The collection efficiencies were neither affected by a change in carbon flow rates from 5 to 8 Ib/hr (2.3 to 3.6 kg/hr) nor by a change in the gas superficial velocity from 27 to 185 ft/min. The VOC concentration in the emission stream from the painting hangar was found to vary by at least a factor of 20 (from 0.18 to 15 ppm) both over the five month period (during which the 15 system tests of about three hours each were conducted) and within a single eight hour work shift.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.