Abstract

Aims Women with invasive carcinoma of the cervix treated by chemo-radiotherapy and brachytherapy may also receive a pelvic sidewall boost using a midline shield (MLS). The purpose of this study was to assess the usefulness of implanted gold grains in detecting the movement of the cervix caused by the insertion of low-dose-rate brachytherapy applicators, and its implications in designing the MLS. Materials and methods The medical records of 42 women with various stages of cervical carcinoma, who were treated by radical chemo-radiotherapy, were reviewed. All of these women underwent examination under anaesthesia (EUA) and a gold-grain insertion to demarcate the vaginal tumour extent, in the antero-posterior and lateral planes, before starting external-beam radiotherapy. The isocentric orthogonal films (simulator films) of external radiotherapy and brachytherapy were compared to assess the change in position of the gold grains and the consequences for the design of the MLS for parametrial and pelvic sidewall boosts. Results A significant shift in the position of the gold grains was noted in both the x (lateral) and the y (cranial/caudal) axes. The median shift of the midline, right and left lateral gold grains was 4.5, 5 and 7 mm in the x axis, whereas it was 10, 8 and 9.5 mm in the y axis, respectively. The median shift in the x and y axes was 5.5 and 9 mm, ranging from 1 to 40 mm and 1 to 45 mm, respectively. The gold grains were shifted cranially in 34 (80%) and laterally in 29 (69%) women. Thirty-two women (76.2%) received parametrial boost radiotherapy, of which 25 (59.5%) women had a customised, pear-shaped shield, and the remaining seven (16.7%) had a straight-sided, rectangular MLS. Four women (9.5%) relapsed locally, and three of them had been treated using a customised shield. In two of these four women, there was an absolute under-dosage of the central pelvis at the tip of the intra-uterine tube by 50% of the parametrial boost dose (5.4 Gy/3 fractions/3 days). Conclusions Insertion of the gold grains during pre-treatment EUA is a useful technique in detecting the movement of the cervix. A significant shift in the position of the gold grains was noted in both the x (lateral) and the y (cranial/caudal) axes. These shifts in the cervix can result in under-dosage of the central pelvis when delivering parametrial boosts with the MLS in place on the basis of the brachytherapy check films. When designing the individualised MLS, the resulting under-dosage could be avoided by taking account of the shift in the gold grain markers and allow the delivery of a more homogenous dose to the pelvis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.