Abstract

We studied the association between the movement of operating room personnel and bacterial contamination of the operative field during 12 clean operations. Settle plates placed on the patient's chest and instrument table were exposed during the operation. As a control, settle plates were exposed in the same locations when no personnel and patients were in the room. Bacterial contamination of the aseptic field was categorized as disseminating (Group A: greater than 42 combined movements) and nondisseminating (Group B: less than 42 combined movements). There were 24 persons in each group. There was a highly significant difference between the two groups in the colony counts on settling plates. More vigorous movement was associated with increased bacterial contamination of the operative field. Low bacterial colony counts were found in the control plates, ruling out environmental sources of contamination. Bacterial fallout correlated with the movement of personnel. Measures to reduce excessive movement in the OR are recommended.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.