Abstract

BackgroundC1-ring osteosynthesis is a valid alternative to posterior C1–C2 or C0–C2 fusion to preserve important C1–C2 motion in the treatment of unstable atlas fractures. Nevertheless, the fixation instruments used in current studies for transoral anterior C1-ring osteosynthesis were not suitable for anterior anatomy of the atlas or did not have reduction mechanism. We therefore present this report to investigate preliminary clinical effects of transoral anterior C1-ring osteosynthesis using a laminoplasty plate in unstable atlas fractures.MethodsFrom January 2014 to December 2017, 13 patients with unstable atlas fractures were retrospectively reviewed. All patients were treated with transoral anterior C1-ring osteosynthesis using a laminoplasty plate. Pre- and postoperative images were obtained to assess reduction of the fracture, internal fixation placement, and bone union. Neurological function, range of motion, and pain levels were evaluated clinically on follow-up.ResultsThe surgeries were successfully performed in all cases. The average follow-up duration was 16.6 ± 4.4 months (range 12–24 months). One patient suffered screw loosening after operation and underwent replacement operation subsequently. Satisfactory clinical outcomes were achieved in all patients with ideal fracture reduction, reliable plate placement, well-preserved range of motion, and neck pain alleviation. All patients achieved bone union of fractures without loss of reduction or implant failure or C1–C2 instability during the follow-up. No vascular or neurological complication was noted during the operation and follow-up.ConclusionsTransoral anterior C1-ring osteosynthesis using a laminoplasty plate is a effective surgical treatment for unstable atlas fractures. This technique has a ingenious reduction mechanism, and can provide satisfactory bone union and preservation of C1–C2 motion.

Highlights

  • C1-ring osteosynthesis is a valid alternative to posterior C1–C2 or C0–C2 fusion to preserve important C1–C2 motion in the treatment of unstable atlas fractures

  • The devices used in previous researches for transoral anterior C1-ring osteosynthesis were not suitable for anterior anatomy of the atlas or did not have reduction mechanism [7,8,9]

  • We retrospectively analyzed the clinical data of 13 patients with unstable atlas fracture who were treated by transoral anterior C1-ring osteosynthesis using a laminoplasty plate presenting with a ingenious reduction procedure, and evaluated the preliminary effects of this technique

Read more

Summary

Introduction

C1-ring osteosynthesis is a valid alternative to posterior C1–C2 or C0–C2 fusion to preserve important C1–C2 motion in the treatment of unstable atlas fractures. The fixation instruments used in current studies for transoral anterior C1-ring osteosynthesis were not suitable for anterior anatomy of the atlas or did not have reduction mechanism. We present this report to investigate preliminary clinical effects of transoral anterior C1-ring osteosynthesis using a laminoplasty plate in unstable atlas fractures. C1-ring osteosynthesis is a wellknown and effective management for unstable atlas fractures to preserve important C1–C2 motion [2]. We retrospectively analyzed the clinical data of 13 patients with unstable atlas fracture who were treated by transoral anterior C1-ring osteosynthesis using a laminoplasty plate presenting with a ingenious reduction procedure, and evaluated the preliminary effects of this technique

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call