Abstract
S–CO2 (Supercritical-CO2) coal-fired power plant is a promising technology for efficient and clean utilization of coal for power generation. The conversion and transfer of the energy and exergy in the power plants with double-reheat and single-reheat processes are studied. With the main gas parameters of 32 MPa/893.15 K, the power generation efficiencies of the S–CO2 coal-fired power plant with double-reheat and single-reheat processes are 49.06% and 48.72%, respectively. The corresponding exergy efficiencies are 48.02% and 47.69%, respectively. The origins of exergy destructions in different units are studied using the Energy Utilization Diagram (EUD) method. The exergy distributions of the power plants are presented. For the power plant with double-reheat process, the work output, the exergy exhaust into the atmosphere, the exergy destruction in combustion process, the exergy destruction in heat transfer processes, the exergy destruction caused by pressure loss, and the exergy destructions in turbo systems account for 48.02%, 9.66%, 20.45%, 17.56%, 1.08%, and 3.23% of the total exergy input of the power plant, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.