Abstract

Abstract Funding Acknowledgements Type of funding sources: None. Introduction Implantable cardioverter defibrillator (ICD) is an effective therapy for primary (PP) and secondary prevention (SP) of sudden cardiac death (SCD). ICD adverse events include inappropriate shocks (IS), device infection and failure. Methods We analysed the data concerning all newly implanted ICDs in our institution from 2011 to 2017. Follow-up data was collected until the end of 2019. Results In total, 507 ICDs were implanted (85.4% male, 57.6 ± 14.0 years-old), 375 (74.0%) for PP and 132 (26.0%) for SP. The mean follow-up was 34.3 ± 23.8 months. ICD delivered therapy in 42.4% of SP and in 28.8% of PP patients (p = 0.15). In PP, shocks were delivered in 25.7% of non-ischaemic heart disease (NIHD) and in 17.6% ischaemic heart disease (IHD) patients (p = 0.81). IS were significantly more common in NIHD patients (13.8% vs 2.4% in IHD group, p < 0.0001). PP patients with NIHD also had a higher shock burden (average of 8.0 ± 17.4 shocks compared to 2.7 ± 3.0 in the IHD group). However, it failed to reach the level of statistical significance (p = 0.052). In SP, the rate of ICD activation and that of IS were similar in both groups (IHD and NIHD). In total, 32.6% of SP patients received appropriate shock (AS) and 5.3% of them received at least one IS (average number of AS and IS being 8.7 ± 11.5 and 1.1 ± 0.4 respectively). Mortality was significantly higher in SP than in PP (34.8% vs 13.9%, p < 0.001). In PP, significantly more deaths occurred among IHD than NIHD patients (18.8% vs 10.0%, p < 0.001). Conclusion The prevalence of AS and IS was relatively higher than reported elsewhere. Same was true for mortality. Interestingly, the rate of IS was somewhat higher in NIHD than in IHD, which was unexpected. ICD outcomes Primary prevention Secondary prevention Total IHD NIHD Total IHD NIHD Patients, n 375 165 210 132 88 44 Patients with ICD activation, n (%) 108 (28.8) 46 (27.9) 62 (29.5) 56 (42.4) 33 (37.5) 22 (50.0) Patientns with AS, n (%) 60 (16.0) 27 (16.4) 33 (15.7) 43 (32.6) 29 (33.0) 14 (31.8) Patientns with IS, n (%) 33 (8.8) 4 (2.4) 29 (13.8) 7 (5.3) 5 (5.7) 2 (4.5) AS delivered (mean ± SD) 5.6 ± 13.3 2.7 ± 3.0 8.0 ± 17.4 8.7 ± 11.5 9.9 ± 12.2 9.7 ± 17.6 IS delivered (mean ± SD) 3.2 ± 5.1 1.2 ± 0.5 3.5 ± 5.4 1.1 ± 0.4 1.0 ± 0 3.2 ± 5.2 Deaths, n (%) 52 (13.9) 31 (18.8) 21 (10.0) 46 (34.8) 32 (36.4) 14 (31.8) Time to death (months, mean ± SD) 20.3 ± 13.9 19.9 ± 12.6 21.1 ± 16.5 27.1 ± 25.7 28.9 ± 24.9 22.6 ± 28.1 ICD, implantable cardioverter defibrillator; IHD, ischemic heart disease; NIHD, non-ischemic heart disease; AS, appropriate shock; IS, inappropriate shock

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.