Abstract

Introduction: : Dental malocclusion is a public health problem and orthodontics is the specialty in charge of diagnosing and treating it, aesthetic brackets are an alternative, the costs are varied, which makes its precision doubtful. Objective: Evaluate the measurement and geometry of the slot of three brands of aesthetic brackets and verify their precision. Material and Methods: Twenty-four aesthetic Roth prescription 0.022” slot polycrystalline ceramic brackets were evaluated in three brands: American Orthodontics (United States), Morelli (Brazil) and Class One (China). Eight samples were measured per group in a specialized laboratory certified in measurement and calibration, the measurements of internal and external height were verified, per mesial and distal; and the parallelism of the slot of each bracket. The results were processed with SPSS 22 and tests of variance (ANOVA), Tukey and Student's t were used. Results: The measurements of the brackets' grooves do not correspond to the measurements announced by the manufacturers, these are greater, however, American Orthodontics is within the tolerance range (p<0.01); the slots in the mesio-distal direction and the lingual vestibule are not parallel in Morelli and Class One. Conclusion: The results of this study indicate that the slots of the supports are oversized, their geometry is not precise and varies greatly between brands and prices. The three-dimensional control of the tooth could be compromised.

Highlights

  • Dental malocclusion is a public health problem and orthodontics is the specialty in charge of diagnosing and treating it, aesthetic brackets are an alternative, the costs are varied, which makes its precision doubtful

  • Prospective, cross-sectional study was carried out in the calibration laboratory "Lo Justo S.A.C." ISO/IEC 17025.16 Twenty-four new, polycrystalline, ceramic, conventional aesthetic brackets, Roth prescription, 0.022” slot that belonged to the same manufacturing batch of each brand were randomly analyzed

  • The nomenclature was A for American Orthodontics, B for Morelli, and C for Class One, to prevent the specialized laboratory staff from identifying each brand

Read more

Summary

Introduction

Dental malocclusion is a public health problem and orthodontics is the specialty in charge of diagnosing and treating it, aesthetic brackets are an alternative, the costs are varied, which makes its precision doubtful. Objective: Evaluate the measurement and geometry of the slot of three brands of aesthetic brackets and verify their precision. Results: The measurements of the brackets' grooves do not correspond to the measurements announced by the manufacturers, these are greater, American Orthodontics is within the tolerance range (p

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call