Abstract

Thoracic transverse process is an important anatomic structure of the spine. Several anatomic studies have investigated the adjacent structures of the thoracic transverse process. But there is still a blank on the morphology of the thoracic transverse processes. The purpose of the cadaveric study is to investigate the morphology of thoracic transverse processes and to provide morphology basis for the pedicle-rib unit (extrapedicular) screw fixation method. Forty-five adult dehydrated skeletons (T1-T10) were included in this study. The length, width, thickness, and the tilt angle (upward and backward) of the thoracic transverse process were measured. The data were then analyzed statistically. On the basis of the morphometric study, 5 fresh cadavers were used to place screws from transverse processes to the vertebral body in the thoracic spine, and then observed by the naked eye and on computed tomography scans. The lengths of thoracic transverse processes were between 16.63±1.59 and 18.10±1.95 mm; the longest was at T7, and the shortest was at T10. The widths of thoracic transverse processes were between 11.68±0.80 and 12.87±1.48 mm; the widest was at T3, and the narrowest was at T7. The thicknesses of thoracic transverse processes were between 7.86±1.24 and 10.78±1.35 mm; the thickest was at T1, and the thinnest was at T7. The upward tilt angles of thoracic transverse processes were between 24.9±3.1 and 3.0±1.56 degrees; the maximal upward tilt angle was at T1, and the minimal upward tilt angle was at T7. The upward tilt angles of T1 and T2 were obviously different from the other thoracic transverse processes (P<0.01). The backward tilt angles of thoracic transverse processes gradually increased from 24.5±2.91 degrees at T1 to 64.5±5.12 degrees at T10. The backward tilt angles were significantly different between each other, except between T5 and T6. In the validation study, screws were all placed successfully from transverse processes to the vertebrae of thoracic spine. The length, width, and thickness of the thoracic transverse processes are suitable for screw placement. And the obvious upward and backward tilt angles provide an excellent screw passage from transverse process to the vertebral body. Screw placement from the transverse processes to the vertebral body is feasible in the thoracic spine. However, there is still some place for improvement of the pedicle-rib unit screw fixation method.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.