Abstract
Objective To analyse the flow characteristics in the true lumen and false lumen,and the relationship between the flow characteristics and the collapse degree of the true lumen using MRI.Methods Eleven patients with acute Stanford type B aortic dissection were examined by true FISP、3D CE MRA、PC cine MRI on a Siemens Sonata 1.5 T.Not only the quantitative data on the hemodynamics such as peak velocity,average velocity,average flow volume,forward volume,retrograde volume and net volume,and the area of the true lumen and false lumen can be acquired,but also the blood flow model,ie the velocity-mapping.Then we analysed the relationship between the flow characteristics and the collapse degree of the true lumen.Results The average area of the false lumen in the proximal descending aorta(about 2 cm distal to the entry)was(8.10±2.93)cm2,and(2.59±0.93)cm2 of the true lumen in the same slice (P<0.05).The average velocity in the false lumen,(2.81±0.73)cm/s,was significantly lower than in the true lumen[(15.52±2.84)cm/s,P<0.01],wheras the average flow(36.32±5.37)ml/s,was not significantly difierent(P>0.05)from the average flow in the false lumen(37.62±24.58)ml/s.The velocity-mapping curve looked like same in the true and false lumen in this level.And in the abdominal aorta(about the level of the hepatic hilar),the average flow(10.46±5.57)cm/s was significantly lower(P<0.05)than in true lumen[(4.04±2.96)cm/s].At this level,the direction of blood flow in the true lumen was retrograde(upward)in the mid and late systolic phase in six patients,and normal in the diastolic phase and early systolic phase,that was to say,bidirectional blood flow can be caught in the true lumen of the abdominal aorta.The collapse degree of the true lumen was closely correlated with the the average velocity and the flow volume in the false Iumen,and the coefficient correlation and P value were 0.931 and 0.000,0.926 and 0.000 respectively.Conclusions PC cine MRI can quantitatively measure the peak velocity,average velocity,average flow volume,forward volume,retrograde volume and net volume,and combined with 3D CE MRA can evaluate the collapse degree of the true lumen.It is important for clinical application in the diagnosis,therapeutic management and the therapeutic opportunity choice of the acute Stanford type B aortic dissection. Key words: Aneurysm,dissecting; Magnetic resonance imaging,cine
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.