Abstract
The aim of this study is to examine the morphology and function and small-caliber, arterial grafts after preservation in the University of Wisconsin solution (UW). Rat carotid arteries were stored in UW (n = 10) or in phosphate-buffered saline (PBS) (n = 10) for 1, 3, 7, and 14 days and were examined with light microscopy (LM) and scanning electron microscopy (SEM). Rat aortic preparations were stored in UW or PBS for 1 hour, 24 hours, 72 hours, 7 days, and 14 days and assessed for functional responses (stimulated contraction and endothelium-dependent relaxation). Segments (5 mm) of rat carotid arteries were stored in UW or PBS for 3 days, 7 days, and 14 days and orthotopically implanted as autografts and allografts. No immunosuppressive or anticoagulant agents were used. After 28 days of implantation, the grafts were assessed for patency and excised for LM and SEM. In UW, the endothelial layer remained intact up to 9 days of storage. In PBS, the endothelial layer showed deterioration after 1 day and was completely lost after 3 days. Functional responses were demonstrated to exist for as long as 7 days storage in UW. In PBS, no responses could be evoked after 24 hours storage. Autografts preserved in UW for 3 days (n = 6), 7 days (n = 6), and 14 days (n = 6) showed patency rates of 83.3%, 66.6%, and 66.6%, respectively, whereas patency rates of allografts were 66.6%, 33.3%, and 33.3%, respectively. Autografts stored in PBS for 3 days (n = 6), 7 days (n = 6), and 14 days (n = 6) showed patency rates of 33.3%, 33.3%, and 50%, respectively, whereas patency rates of allografts were 16.7%, 0%, and 33.3%, respectively. The UW preserved autografts showed normal morphology. All other groups showed vessel wall degeneration which in the allograft groups, were accompanied by lymphocellular infiltration. In conclusion, the endothelial layer and vessel wall of arteries are adequately preserved in UW. Functional responses are retained up to 14 days storage in UW, but, are lost after 24 hours storage in PBS. Autograft implantation studies accordingly show good performance of arterial segments preserved in UW, whereas allografts are subject to degradation as a result of rejection.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.