Abstract

Transmission electron microscopy has been used to evaluate the primary particle size distributions and aggregate structure of a fumed silica sample. The primary particle size distribution within an individual aggregate is narrow, with a geometric standard deviation of ∼ 1.2. The distributions of maximum diameters, projected areas, and average primary particle diameters were all skewed, and all were better described by a log-normal distribution than a normal distribution. The data confirmed the fractal description of the fumed silica aggregate structure, with a mass fractal dimension of 1.86. The fractal prefactor or lacunarity was evaluated from the aggregate volume and the maximum particle dimension, and found to have a value of 0.83 for this sample.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.