Abstract

ObjectiveTo evaluate the morphological asymmetry of pelvic rings existing in healthy individuals in terms of three‐dimensional (3D) geometric shapes.MethodsThis study was a retrospective self‐control study. CT images of healthy pelvises, scanned from Jan 2014 to Jan 2019, were taken from 159 subjects (88 males and 71 females) aged 20 to 59 years (39.1 ± 8.7 years). Digital pelvic ring models were reconstructed from CT images and then flipped over the corresponding sagittal planes to obtain their mirrored models. A 3D deviation analysis of a pelvic ring was conducted between the original model and its mirrored model via model registration and quantification of the geometric differences. Next, the pelvic rings were split to the left and right hipbones. The same flipping procedures as done by pelvic rings were performed for left hipbones to obtain their mirrored models. A 3D deviation analysis was also performed between the left and right hip bones. Quantitative variables representing deviation mainly included the average deviation (AD) and the maximum deviation (MD). MDs over 4 mm and 10 mm were deemed as critical levels for evaluating the severity of asymmetry as per Matta's scoring system. The quantitative assessments of the asymmetry covered pelvic rings, bilateral hip bones and the specific anatomic regions of a hip bone.Results157 out of 159 pelvic rings (98.74%) had more than 4 mm of the MD and 27 (16.98%) of them exceeded 10 mm of the MD. The MD of pelvic rings was 1.23 times as high as that for the bilateral hip bones (7.46 mm vs. 6.08 mm, P < 0.05). The ADs of pelvic rings and bilateral hip bones were 1.28 mm and 0.94 mm, respectively (P < 0.05); 2.27% of the surface points of a pelvic ring had more than 4 mm geometric deviations compared with its mirrored model, while 0.59% (P < 0.05) of bilateral hip bones were on the same level of deviation. 119 out of 159 pelvic iliac crests (74.8%) had MDs more than 4 mm, and 15 (9.4%) reached 10 mm or more. Only 15 (9.4%) pelvises presented asymmetric features in the area of obturator foramen where the MDs exceeded 4 mm.ConclusionsPelvic asymmetry exists in the general population, but 3D geometric symmetry is present in specific anatomic regions. It implies that restoring the 3D symmetry of specific anatomic regions is more reliable than “restoring the symmetry of pelvic ring” in pelvic ring reduction or pelvic fixation design.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call