Abstract
Purpose: To compare Reading Center (RC) cup-to-disc ratio (CDR) assessment from stereoscopic photographs with clinician estimation in a uveitis clinical trial.Methods: Clinical estimation of CDR was performed by ophthalmologists via dilated biomicroscopy. Photographic evaluation was performed at an independent RC by masked, certified evaluators. Quality control was performed by repeat grading of 77 randomly selected images.Results: Among 479 eyes with uveitis, 353 eyes had clinical and photographic grades for CDR. Agreement between clinical and RC grading was fair, with exact agreement of 29%. Agreement within 0.1 and 0.2 CDR was 70 and 93%, respectively (weighted κ = .34). Intergrader reproducibility at the RC was better (weighted κ = .59, ICC 0.74).Conclusion: Morphologic assessment of cup to disc ratio is an important outcome and safety measure for determining glaucomatous damage in clinical trials. Masked RC measurements are more likely to be accurate than biomicroscopic grading in identifying meaningful anatomical change associated with glaucoma.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.