Abstract

Abstract Introduction Tendinopathy is a term used to describe a clinical presentation of pain and dysfunction, which, at times, is accompanied by pathologic structural changes in the tendon matrix. Jumper's knee has been studied for some time, however the etiology is still unknown. The deep fibers of the proximal region are the most affected area in tendinopathies affecting the patellar tendon. Ultrasound (US) scanning may have the greatest sensitivity for confirming clinically diagnosed patellar tendinopathy compared with other imaging techniques such as magnetic resonance. Some studies have found that a minimum of six months is required to observe significant structural changes, although other studies reveal that structural changes can be visible in a shorter period of time. Thus, sonography has been used to evaluate quantitative variables such as thickness, echogenicity, texture measures and the internal tendon matrix. Objective The purpose of this study was to evaluate the sonographic behavior of morpho-textural changes of the patellar tendon in professional male volleyball players over a one year season. Material and Methods This is an observational, longitudinal and analytical study. A sample of 66 patellar tendons from 33 volleyball players of the Spanish super league was recruited, with an average of: 28 years, 86kg and 192cm. An ultrasound scan was performed using the Sonosite Titan ultrasound system, L38, 5–10 MHz, with a cross section of 5mm from the lower pole of the patella. Two depths were analyzed: a.39mm: echogenicity, echogenicity variation, circularity, width and thickness. b.24mm: entropy and contrast. Statistical analysis and analysis of variance (ANOVA) was performed for repeated measures and, in addition, the effect size was calculated with Cohen's d. The confidence interval was 95%. SPSS Statistics software was used. Results For textural variables: contrast increased significantly with an average effect size, and entropy showed no significant difference. Circularity was significantly lower. Width was shown to be significantly greater, with an average effect size, while thickness was reduced significantly. Regarding echogenicity, no significant changes were detected and variation in echogenicity did not show significant changes. Conclusions Imaging analysis could be a potential tool to detect changes in the pattern of patellar tendons. Some morpho-textural changes were found in male volleyball players: the textural contrast variable increases significantly throughout the annual season, meaning that the tendon becomes slightly flatter and loses circularity in its transverse section. The entropy and echogenic parameters obtained from the gray-scale histogram did not reveal any significant changes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.