Abstract
Particle and Heavy Ion Transport Code System (PHITS) is a Monte Carlo simulation program used for transport and collision of nearly all particles over wide energy range. One of its useful features for accelerator facility design is the calculation of dose distribution. This paper describes how the geometry of the bunker for low electron beam accelerator in Nuklear Malaysia (NM) was modelled and used to calculate the equivalent dose caused by the radiation for specific region in the bunker by using PHITS. The dose distribution and energy deposition were obtained. Finally, the simulation results are compared to the measured value from the dose measurement testing inside the bunker facility and found both results are in a good agreement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Materials Science and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.