Abstract

For preclinical assessments of several radiopharmaceuticals, photon specific absorbed fractions (SAFs) were evaluated using the voxel-based mouse phantom. The sources were assumed to be mono-energetic in the photon energy range from 10 keV to 4 MeV. The radiation transport was simulated using the Monte Carlo method. Consequently, it was confirmed that the photon SAFs for organ self-absorption are dependent on the masses of the source/target organs. It would appear that the photons SAFs for organ self-irradiation are expressed by a continuous function of photon energy emitted by the source. The photon SAFs for organ cross-irradiation might be subject to the geometry effect such as size and shape of source/target and distance between the source and target.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.