Abstract

Radiation processing plants are designed to deliver a prescribed dose to product materials within the acceptable uniformity to meet the national standards. The dose uniformity ratios for four different product geometries of a proposed 37 PBq (10(6) Ci) 60Co-based, multi-product irradiator facility in India are evaluated using the Monte Carlo method for various product densities, 0.15 g cm-3, 0.4 g cm-3, and 0.6 g cm-3. The calculations are also carried out using the point kernel method for comparison purposes. The agreement between Monte Carlo and point kernel methods is within 3 to 15%. The suitable product geometry is identified based on dose uniformity ratios.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.