Abstract

This paper employs Monte Carlo simulations of the performance of a transition radiation detector (TRD). The program has been written for the TRD in the ZEUS spectrometer, which separates electrons from hadrons in the momentum range between 1 and 30 GeV/ c. Both, total charge method and cluster counting method were simulated taking into account various experimental parameters. In particular, it was found that the cluster counting method relies on a quantitative understanding of the background originating from the production of δ-electrons by charged particles. The results of the Monte Carlo calculations are in agreement with experimental data obtained with prototypes within a systematic uncertainty of 20%. We applied our Monte Carlo program to studies in order to find an optimum layout for the TRD within available space in the ZEUS spectrometer. In this context, the performance of TRD layouts with different geometries and materials has been evaluated comprehensively. The geometry found by optimization promises an improvement on hadron suppression by a factor of about two for both methods compared with present results from test measurements. Applying algorithms for a detailed analysis of the energy and space distributions of the clusters in the TRD, hadrons in the momentum range from 1 to 30 GeV/ c can be suppressed to a level of less than 2%. This method of cluster analysing improves the suppression of hadrons by a factor of about two compared to the total charge method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call