Abstract

Introduction: Globally, the need for radiotherapy as a part of cancer management increases every year. Thus, the shielding for megavoltage radiotherapy rooms is of great importance. Materials and Methods: In the present study, 14 types of developed high-density concrete with densities ranging from 2.45 to 5.11 were simulated by using Monte Carlo method. The linear attenuation coefficient and the tenth value layer were also calculated. These dosimetric parameters were investigated for megavoltage photon beam spectra for various energies (4, 6, 10, 15, and 18 MeV) of the Varian linac and 60Co gamma rays. The results of simulation were compared with the available published results. Results: The results showed that the attenuation of high-energy photons is primarily administered by the atomic number and density of the concrete. Moreover, the variation of attenuation coefficient with density was not completely linear. Conclusion: It was concluded that the attenuation of high-energy photons not only depends on the density of concrete, but also on the atomic number of its composing elements. dependent on density of concrete but also on atomic number of composing elements.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.