Abstract

Visualizing macromolecular complexes by single-particle electron microscopy (EM) entails stringent biochemical purification, specimen preparation, low-dose imaging, and 3D image reconstruction. Here, we introduce the "monolayer purification" method, which employs nickel-nitrilotriacetic acid (Ni-NTA) functionalized lipids for simultaneously purifying His-tagged complexes directly from cell lysates while producing specimens suitable for single-particle EM. The method was established by using monolayers containing Ni-NTA lipid to specifically adsorb His-tagged transferrin-transferrin receptor (Tf-TfR) complexes from insect and mammalian cell extracts. The specificity and sensitivity of the method could be improved by adding imidazole to the extracts. The monolayer-purified Tf-TfR samples could be vitrified and used to calculate a 3D reconstruction of the complex. Monolayer purification was then used to rapidly isolate ribosomal complexes from bacteria by overexpressing a single His-tagged ribosomal subunit. The resulting monolayer samples allowed calculation of a cryo-EM 3D reconstruction of the Escherichia coli 50S ribosomal subunit.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call